Saltar al contenido
YuanGan Technology
Multi-Parameter Online Analyzer Kit YG-NB/01 YG-NB/01

Kits & Rapid Detection

Multi-Parameter Online Analyzer Kit YG-NB/01

YG-NB/01Former model: YG-WMSX02/KB

Las especificaciones detalladas se muestran en inglés.

The multi-parameter online water quality analyzer kit is a drinking-water quality monitoring kit developed by YuanGan for system integrators. Its minimalist, compact design makes system integration easy. Monitored parameters include turbidity, disinfectant (free chlorine / total chlorine / chlorine dioxide / ozone / trichloroisocyanuric acid), pH, ORP, conductivity and temperature. It is mainly used for online water quality monitoring in water treatment plants, distribution networks, secondary water supply, network ends, swimming pools and other water treatment equipment.

Typical applications

  • Water Treatment Plants
  • Distribution Network
  • Secondary Water Supply
  • Network Ends
  • Swimming Pools
  • Online water quality monitoring of other water treatment equipment

yan@yuangankeji.com · +86-400-1688-667 · WhatsApp +86 151 7883 0466

Key features

  • 01

    Multi-parameter

    Integrated design monitors turbidity, disinfectant, temperature, pH or other optional parameters at the same time

  • 02

    High accuracy

    Stable, accurate long-term measurement at tap-water (0.1–1 NTU) and purified-water (0.001–0.1 NTU) levels

  • 03

    High reliability

    Digital sensors and instrument components, extensively optimized internally for online water analysis, deliver high reliability

  • 04

    Low maintenance

    Compact structure with standard RS485 Modbus-RTU communication

Technical Specifications

ItemSpecificationValue
SystemPower5 W
WeightApprox. 4.5 kg
Dimensions (W × H × D)370 × 470 × 140 mm (W × H × D)
Operating humidity≤ 95%RH (non-condensing)
Sample flow rate500–2000 mL/min
Inlet pressure≤ 0.6MPa
Operating temperature-5 °C – 45 °C
Communication interfaceRS485 Modbus RTU communication protocol
TurbidityMeasurement method90° light scattering method (laser light source)
Light source660nm laser
Range0–100 NTU
Resolution0.0001 NTU(<1 NTU), 0.001 NTU(≥1 NTU)
Limit of detection0.005 NTU
Sample flow rate0.3–2L/min
Zero drift≤1.5%
Reading stability≤1.5%
Accuracy2% or 0.02 NTU (whichever is greater); (based on Formazin primary standard at 25 °C)
Repeatability1% or 0.006 NTU (whichever is greater); (based on Formazin primary standard at 25 °C)
Response time (T90)≤120 s
Calibration methodFactory-calibrated, using the default calibration curve; One-point calibration, Formazin two-point calibration, 2- to 6-point custom calibration
Disinfectant (free chlorine, chlorine dioxide (high-purity), ozone, total chlorine, trichloroisocyanuric acid)Measurement methodReagent-free electrochemical three-electrode amperometric system
Repeatability±3%
Resolution0.001 mg/L
Limit of detection0.030 mg/L or lower
Range0–5/20 mg/L
Accuracy±3% (DPD correlation error ±10% or ±0.05 mg/L whichever is greater)
Response time (T90)≤90 s
Calibration methodOne- or two-point calibration
Sample pH range4–9
TemperatureMeasurement methodThermistor method
Range-5 °C ~ 60 °C
Resolution0.1 °C
Accuracy±0.4 °C
Repeatability0.2 °C
Response time (T90)≤25 s
Calibration methodOne-point calibration
pHMeasurement methodElectrochemical (electrode) method
Range0-14
Resolution0.01
Accuracy±0.5
Repeatability0.01
Response time (T90)≤60 s
Calibration methodOne-, two- or three-point calibration
ORP (optional)Measurement methodElectrochemical (electrode) method
Range-2000 mV ~ +2000 mV
Resolution1 mV
Limit of detection1 mV
Accuracy± 20 mV
Repeatability10 mV
Response time (T90)≤60 s
Calibration methodOne- or two-point calibration
Conductivity (optional)Measurement methodConductivity cell method (automatic temperature compensation)
Range0–20000 μS/cm, pure-water electrode: 0–20 μS/cm
Resolution0.01uS/cm
Limit of detection6uS/cm
Accuracy±0.8%F.S. pure-water electrode: 3%FS
Repeatability0.4%F.S.
Response time (T90)≤30 s
Calibration methodOne-point calibration
TDS (optional)Measurement methodConductivity cell method (automatic temperature compensation)
Range0–10000 mg/L pure-water electrode: 0–10 mg/L
Resolution0.01 mg/L
Limit of detection3 mg/L
Accuracy± 0.8%F.S pure-water electrode: 3%F.S
Repeatability0.4%F.S
Response time (T90)≤30 s
Calibration methodOne-point calibration
Dissolved oxygen (optional)Measurement methodFluorescence method
Range0–20 mg/L(0–200% saturation)
Resolution0.01 mg/L
Repeatability±3% or ±0.2mg/Lwhichever is greater
Limit of detection0.1 mg/L
Response time (T90)≤60 s
Accuracy±3% or ±0.2mg/Lwhichever is greater
Calibration methodAir calibration
(Note: specifications may change with product improvements; YuanGan reserves the right to modify them.)

Request a quote for YG-NB/01

Tell us your application, parameters and volume. Our export team replies by email or WhatsApp.

yan@yuangankeji.com · +86-400-1688-667 · WhatsApp +86 151 7883 0466