Multi-Parameter Online Analyzer Kit YG-NB/01
As especificações detalhadas são exibidas em inglês.
The multi-parameter online water quality analyzer kit is a drinking-water quality monitoring kit developed by YuanGan for system integrators. Its minimalist, compact design makes system integration easy. Monitored parameters include turbidity, disinfectant (free chlorine / total chlorine / chlorine dioxide / ozone / trichloroisocyanuric acid), pH, ORP, conductivity and temperature. It is mainly used for online water quality monitoring in water treatment plants, distribution networks, secondary water supply, network ends, swimming pools and other water treatment equipment.
Typical applications
- Water Treatment Plants
- Distribution Network
- Secondary Water Supply
- Network Ends
- Swimming Pools
- Online water quality monitoring of other water treatment equipment
yan@yuangankeji.com · +86-400-1688-667 · WhatsApp +86 151 7883 0466
Key features
- 01
Multi-parameter
Integrated design monitors turbidity, disinfectant, temperature, pH or other optional parameters at the same time
- 02
High accuracy
Stable, accurate long-term measurement at tap-water (0.1–1 NTU) and purified-water (0.001–0.1 NTU) levels
- 03
High reliability
Digital sensors and instrument components, extensively optimized internally for online water analysis, deliver high reliability
- 04
Low maintenance
Compact structure with standard RS485 Modbus-RTU communication
Technical Specifications
| Item | Specification | Value |
|---|---|---|
| System | Power | 5 W |
| Weight | Approx. 4.5 kg | |
| Dimensions (W × H × D) | 370 × 470 × 140 mm (W × H × D) | |
| Operating humidity | ≤ 95%RH (non-condensing) | |
| Sample flow rate | 500–2000 mL/min | |
| Inlet pressure | ≤ 0.6MPa | |
| Operating temperature | -5 °C – 45 °C | |
| Communication interface | RS485 Modbus RTU communication protocol | |
| Turbidity | Measurement method | 90° light scattering method (laser light source) |
| Light source | 660nm laser | |
| Range | 0–100 NTU | |
| Resolution | 0.0001 NTU(<1 NTU), 0.001 NTU(≥1 NTU) | |
| Limit of detection | 0.005 NTU | |
| Sample flow rate | 0.3–2L/min | |
| Zero drift | ≤1.5% | |
| Reading stability | ≤1.5% | |
| Accuracy | 2% or 0.02 NTU (whichever is greater); (based on Formazin primary standard at 25 °C) | |
| Repeatability | 1% or 0.006 NTU (whichever is greater); (based on Formazin primary standard at 25 °C) | |
| Response time (T90) | ≤120 s | |
| Calibration method | Factory-calibrated, using the default calibration curve; One-point calibration, Formazin two-point calibration, 2- to 6-point custom calibration | |
| Disinfectant (free chlorine, chlorine dioxide (high-purity), ozone, total chlorine, trichloroisocyanuric acid) | Measurement method | Reagent-free electrochemical three-electrode amperometric system |
| Repeatability | ±3% | |
| Resolution | 0.001 mg/L | |
| Limit of detection | 0.030 mg/L or lower | |
| Range | 0–5/20 mg/L | |
| Accuracy | ±3% (DPD correlation error ±10% or ±0.05 mg/L whichever is greater) | |
| Response time (T90) | ≤90 s | |
| Calibration method | One- or two-point calibration | |
| Sample pH range | 4–9 | |
| Temperature | Measurement method | Thermistor method |
| Range | -5 °C ~ 60 °C | |
| Resolution | 0.1 °C | |
| Accuracy | ±0.4 °C | |
| Repeatability | 0.2 °C | |
| Response time (T90) | ≤25 s | |
| Calibration method | One-point calibration | |
| pH | Measurement method | Electrochemical (electrode) method |
| Range | 0-14 | |
| Resolution | 0.01 | |
| Accuracy | ±0.5 | |
| Repeatability | 0.01 | |
| Response time (T90) | ≤60 s | |
| Calibration method | One-, two- or three-point calibration | |
| ORP (optional) | Measurement method | Electrochemical (electrode) method |
| Range | -2000 mV ~ +2000 mV | |
| Resolution | 1 mV | |
| Limit of detection | 1 mV | |
| Accuracy | ± 20 mV | |
| Repeatability | 10 mV | |
| Response time (T90) | ≤60 s | |
| Calibration method | One- or two-point calibration | |
| Conductivity (optional) | Measurement method | Conductivity cell method (automatic temperature compensation) |
| Range | 0–20000 μS/cm, pure-water electrode: 0–20 μS/cm | |
| Resolution | 0.01uS/cm | |
| Limit of detection | 6uS/cm | |
| Accuracy | ±0.8%F.S. pure-water electrode: 3%FS | |
| Repeatability | 0.4%F.S. | |
| Response time (T90) | ≤30 s | |
| Calibration method | One-point calibration | |
| TDS (optional) | Measurement method | Conductivity cell method (automatic temperature compensation) |
| Range | 0–10000 mg/L pure-water electrode: 0–10 mg/L | |
| Resolution | 0.01 mg/L | |
| Limit of detection | 3 mg/L | |
| Accuracy | ± 0.8%F.S pure-water electrode: 3%F.S | |
| Repeatability | 0.4%F.S | |
| Response time (T90) | ≤30 s | |
| Calibration method | One-point calibration | |
| Dissolved oxygen (optional) | Measurement method | Fluorescence method |
| Range | 0–20 mg/L(0–200% saturation) | |
| Resolution | 0.01 mg/L | |
| Repeatability | ±3% or ±0.2mg/Lwhichever is greater | |
| Limit of detection | 0.1 mg/L | |
| Response time (T90) | ≤60 s | |
| Accuracy | ±3% or ±0.2mg/Lwhichever is greater | |
| Calibration method | Air calibration | |
| (Note: specifications may change with product improvements; YuanGan reserves the right to modify them.) |