Single-Parameter Analyzers
High Turbidity / SS / Sludge Online Analyzer
Les spécifications détaillées sont affichées en anglais.
The high-turbidity / suspended solids / sludge concentration online analyzer is a product independently developed by YuanGan for online water quality monitoring. A universal controller works together with YuanGan T3-series high-range turbidity / suspended solids / sludge concentration sensors to continuously monitor turbidity / suspended solids / sludge concentration in the solution. The data can be sent to a recorder through the transmitter output for remote monitoring and logging, or connected to a computer through the RS485 interface using the Modbus-RTU protocol, so the computer can monitor and record the instrument.
Typical applications
- Industrial
- Municipal Sewage Network
- Wastewater Treatment Plants
yan@yuangankeji.com · +86-400-1688-667 · WhatsApp +86 151 7883 0466
Key features
- 01
Automatic sensor recognition
Plug and play
- 02
Offline calibration
Supports offline sensor calibration
- 03
Sensor with beveled optical window
Bubbles do not easily adhere
- 04
Sealed structure
Sensor suitable for deep water or high pressure
- 05
Optional air-blow cleaning for the sensor
Enables maintenance-free operation
Technical Specifications
| Controller parameters | |
|---|---|
| Peak power: | 6 W |
| Operating voltage: | AC100–240 V; DC24 V (optional) |
| Operating temperature: | 0–60°C |
| Operating humidity: | 10%~95%RH (non-condensing) |
| Storage temperature: | -15–65°C (sensor not included) |
| Screen size: | 2.8 -inch LCD display |
| Relays: | One set each of high / low limit alarms (250VAC/3A), normally open contact relay |
| Digital output: | RS485, Modbus protocol |
| Analog output: | Isolated 4–20 mA transmitter output, max. loop 750 Ω, ±0.2% F.S. |
| Overall dimensions: | 100 × 100 × 150 mm (W × H × D) |
| Cut-out dimensions: | 92.5⁺¹ mm × 92.5⁺¹ mm |
| Sensor parameters | |
| Range: | Turbidity 0–4000 NTU Suspended solids / sludge concentration 0–30000 mg/L |
| Resolution: | Turbidity 0.1 NTU Suspended solids / sludge concentration 0.1 mg/L |
| Accuracy: | 5%FS |
| Repeatability: | 2.5%FS |
| Measurement method: | Light scattering method (ISO 7027) |
| Light source: | 860nm infrared laser LED |
| Calibration method: | Two-point calibration |
| Operating pressure: | ≤0.6 MPa or water depth ≤60 m |
| (Note: specifications may change with product improvements; YuanGan reserves the right to modify them.) | |
Ordering Information
| Product Name | Model |
|---|---|
| Universal controller | YG-UT/KA |
| Turbidity sensor (without air blow, ABS housing) | YG-T3/41 |
| Turbidity sensor (without air blow, 316 stainless steel housing) | YG-T3/42 |
| Turbidity sensor (air-blow version, ABS housing) | YG-T3/31 |
| Turbidity sensor (air-blow version, 316 stainless steel housing) | YG-T3/32 |
| Suspended solids / sludge concentration sensor (without air blow, ABS housing) | YG-T3/S3 |
| Suspended solids / sludge concentration sensor (without air blow, 316 stainless steel housing) | YG-T3/S4 |
| Suspended solids / sludge concentration sensor (air-blow version, ABS housing) | YG-T3/S1 |
| Suspended solids / sludge concentration sensor (air-blow version, 316 stainless steel housing) | YG-T3/S2 |